600W Ballast
Click image to view full size image
Product: Views:384600W Ballast 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2018-07-06 18:27
  Inquiry
Details

Specification:

1. Don’t operate the ballast before you read and fully comprehend the instructions.

2. The start voltage of the ballast is a maximum of 4.5 KV; it might be dangerous for people

and nearby equipment.Please pay attention to the danger and don’t touch any electric object

when operating the ballast.

3. The ballast can’t ignite lamps when it is hot. When reigniting the lamp after shutting

down, please wait 3 minutes to give time for the lamp to cool down.

4. The ballast can’t be installed and operated under circumstances with explosive/volatile

gas; it can’t be started near flammable gas or liquid.

5. There is no voltage insulation between the input end and output end, so there will be damage if contacting the output end directly to ground.


INPUT

Vin: 170Vac - 265 Vac

Rated Vin: 230/240 Vac Imax:3.7A

Protection of over current input: interior fuse

PF: > 0.98

THD: < 10%

Frequency in: 50Hz/60Hz

OUTPUT

Power Out: > 580W

V Lamp: 75 Vac - 160 Vac

Frequency out: > 60KHz

Current Crest Factor(CCF): < 1.7

Voltage of Open Circuit: > 200V

Ignition Voltage: < 4KV

Efficiency: > 94% (240 Vac)

CHARACTER OF PROTECTION

Short circuit Protection:YES

Open: YES

Strike Failure Protection: YES

Thermo Protection: YYEESS

EOL: YES

PHYSICAL SPECIFICATIONS

Wiring Distance: ≤20M

Working Temperature range: -30°C ~ +50°C

Maximum Case Temperature: 80°C


http://www.hydroponics4grow.com/

Inquiry